Home  |  Products  |  BSA Trailer Pumps  |  BSA 14000 HP-E 8" Trailer-Mounted Concrete Pump   Spec Sheet   Spec Sheet Spanish   Find a Distributor

Putzmeister BSA 14000 HP-E 8" Trailer-Mounted Concrete Pump

The BSA 14000 HP-E 8" is a powerful pump with maximum volume at the greatest distances. It has maximum output of 116 cubic yards per hour at pressures up to 2,176 psi with 8-inch x 83-inch material cylinders to fit any job requirement.

Specification Tables

Click the tab(s) below for more information.

Performance
Maximum theoretical output* - rod 116 yd³/hr (89m³/hr)
Maximum theoretical output* - piston 78 yd³/hr (60m³/hr)
Maximum theoretical pressure* - rod 2,176 psi (150 bar)
Maximum theoretical pressure* - piston 3,190 psi (220 bar)^
Technical Information
Material cylinders 8" x 83" (200 x 2,100mm)
Variable volume 0 to full
Chromed cylinders Standard
Hydraulic system FFH-EL
Hydraulic system pressure 5,075 psi (350 bar)
Hydraulic cylinders 6.3" x 3.5" (160 x 90mm)
Outlet diameter ZX125
Maximum size aggregate 2.5" (63mm)
Valve & Hopper
S-Valve S-1812D
Hopper model RS 905HF
Hopper capacity 21.2 ft³ (600L)
Hopper height 51" (1,295mm)
Maximum strokes per minute - rod 22
Maximum strokes per minute - piston 15
Dimensions
Trailer type Tandem axles
Length 308" (7,830mm)
Width 101" (2,560mm)
Height 142" (3,600mm)
Approximate weight 23,840 lbs (10,810kg)

* Specifications subject to change without prior notice. Maximum theoretical values listed above. Maximum output and pressure cannot be achieved simultaneously.

^ Special equipment configurations required to operate on piston side.

Minimum slump and maximum aggregate size are dependent upon concrete mix design, site conditions and pipeline diameter. Special equipment configurations required to operate on piston side. Photos and drawings are for illustrative purposes only. For available options, please contact the factory.
 back to top
Engine Specifications
Diesel Engine / Motor 460V/60hz
Power 2x 248 hp (185kW)

* Specifications subject to change without prior notice. Maximum theoretical values listed above. Maximum output and pressure cannot be achieved simultaneously.

^ Special equipment configurations required to operate on piston side.

Minimum slump and maximum aggregate size are dependent upon concrete mix design, site conditions and pipeline diameter. Special equipment configurations required to operate on piston side. Photos and drawings are for illustrative purposes only. For available options, please contact the factory.
 back to top